HP-UX
[HP-UX] arraydsp
by 레이루이
2008. 4. 30.
auto-array list
# export LANG=C
# arraydsp -i
Arrays known to the ARMServer:
Array with S/N: 00000035B6BE Alias: AUTO1
Array with S/N: 0000003773CA Alias: AUTO2 auto-array 상세정보
# arraydsp -a AUTO1
Vendor ID = HP
Product ID = C5447A
Array serial number = 00000035B6BE
Array alias = AUTO1
----------------------------------------------------
Array State = READY
Server name = vandb
Array type = 3
Mfg. Product Code = IJMTU00004
--- Disk space usage --------------------
Total physical = 52099 MB *
Allocated to LUNs = 32011 MB *
Used as Active Hot spare = 8683 MB *
Used by non-included disks = 0 MB *
Used for Redundancy = 11405 MB *
Unallocated (avail for LUNs) = 0 MB *
-----------------------------------------
Vendor ID = HP
Product ID = C5447A
Array serial number = 00000035B6BE
Array alias = AUTO1
----------------------------------------------------
LUN 0:
Capacity (MB=2^20) = 16000 MB *
Maximum block addr = 32768000
Block length = 512
LUN 1:
Capacity (MB=2^20) = 16011 MB *
Maximum block addr = 32790528
Block length = 512
Total capacity allocated to LUNs = 32011 MB *
Information for disk in slot A4:
Disk State = INCLUDED
Vendor = SEAGATE
Product ID = ST39103LC
Capacity = 8683 MB *
Max. block addr = 17783111
Block length = 512
Serial number = 05620000U009
Firmware revision = HP02
Drive ID number = FFFFFFFD E07C220
Volume set serial no. = 114C7 2
Information for disk in slot B4:
Disk State = INCLUDED
Vendor = SEAGATE
Product ID = ST39103LC
Capacity = 8683 MB *
Max. block addr = 17783111
Block length = 512
Serial number = 31400000W009
Firmware revision = HP02
Drive ID number = FFFFFFFD EB99D40
Volume set serial no. = 114C7 2
Information for disk in slot A5:
Disk State = INCLUDED
Vendor = SEAGATE
Product ID = ST39103LC
Capacity = 8683 MB *
Max. block addr = 17783111
Block length = 512
Serial number = 29780000U009
Firmware revision = HP02
Drive ID number = FFFFFFFD EBF4220
Volume set serial no. = 114C7 2
Information for disk in slot B5:
Disk State = INCLUDED
Vendor = SEAGATE
Product ID = ST39103LC
Capacity = 8683 MB *
Max. block addr = 17783111
Block length = 512
Serial number = 29870000U009
Firmware revision = HP02
Drive ID number = FFFFFFFD ECAC0B0
Volume set serial no. = 114C7 2
Recovery Maps are on this disk.
Information for disk in slot A6:
Disk State = INCLUDED
Vendor = SEAGATE
Product ID = ST39103LC
Capacity = 8683 MB *
Max. block addr = 17783111
Block length = 512
Serial number = 010300001009
Firmware revision = HP02
Drive ID number = FFFFFFFD EE1A6F1
Volume set serial no. = 114C7 2
Recovery Maps are on this disk.
Information for disk in slot B6:
Disk State = INCLUDED
Vendor = SEAGATE
Product ID = ST39103LC
Capacity = 8683 MB *
Max. block addr = 17783111
Block length = 512
Serial number = 30530000W009
Firmware revision = HP02
Drive ID number = FFFFFFFD EAC56D0
Volume set serial no. = 114C7 2
Total capacity of all installed physical disks = 52099 MB *
Information for controller X:
Vendor ID = HP
Product ID = C5447A
Array serial number = 00000035B6BE
Alias = AUTO1
Primary = FALSE
SCSI Address = 1
Serial number = R975ADH708551111
Paired serial number = R96LADH640801111
Product revision = HP62
Information for controller Y:
Vendor ID = HP
Product ID = C5447A
Array serial number = 00000035B6BE
Alias = AUTO1
Primary = TRUE
SCSI Address = 0
Serial number = R96LADH640801111
Paired serial number = R975ADH708551111
Product revision = HP62
Vendor ID = HP
Product ID = C5447A
Array serial number = 00000035B6BE
Array alias = AUTO1
----------------------------------------------------
Overall State of Array = READY
Array configuration:
Active Hot Spare Desired = ENABLED
Auto Include = ENABLED
Auto Rebuild = ENABLED
Rebuild Priority = HIGH
Capacity Depletion Threshold = 0%
Write Working Set Interval = 8640 seconds
Language = ENGLISH
Log Full Warning = DISABLED
Volume Set Partitioning = DISABLED
Format Pattern Fill = DISABLED
Subsystem Type ID = 12
LUN Creation Limit = 8
Maximum LUN Creation Limit = 8
Array SCSI configuration:
Controller X SCSI Address = 1
Controller Y SCSI Address = 0
Write Cache = ENABLED
Read Cache = DISABLED
SCSI Parity Checking = ENABLED
SDTR = ENABLED
WDTR = ENABLED
Terminator Power = ENABLED
Unit Attention = ENABLED
Disable Remote Reset = ENABLED
Secondary Controller Offline = DISABLED
Very Early Busy = DISABLED
Queue Full Threshold = 1952
Maximum Queue Full Threshold = 1952
Simplified Resiliency Setting = Normal
Single Controller Warning = ENABLED
Lock Write Cache On = TRUE
Disable NVRAM on WCE False = FALSE
Disable NVRAM with One Ctrlr = TRUE
Disable NVRAM on UPS absent = FALSE
Force Unit Access Response = 0
Disable Read Hits = FALSE
Resiliency Threshold = 4
Vendor ID = HP
Product ID = C5447A
Array serial number = 00000035B6BE
Array alias = AUTO1
----------------------------------------------------
Raid 0/1 blocks = 13359872
Raid 0/1 block length = 512
Raid 0/1 capacity = 6523 MB *
Vendor ID = HP
Product ID = C5447A
Array serial number = 00000035B6BE
Array alias = AUTO1
----------------------------------------------------
Fan F1 = GOOD
Fan F2 = GOOD
Fan F3 = GOOD
Power supply PS1 = GOOD
Power supply PS2 = GOOD
Power supply PS3 = GOOD
Controller X:
Overall state = GOOD
Battery #0 state = GOOD
Battery #1 state = GOOD
DRAM #0 state = GOOD
NVRAM #0 state = GOOD
NVRAM #1 state = GOOD
Controller Y:
Overall state = GOOD
Battery #0 state = GOOD
Battery #1 state = GOOD
DRAM #0 state = GOOD
NVRAM #0 state = GOOD
NVRAM #1 state = GOOD